The purpose of this study was to measure the thermodynamic properties of 1-hexyl-3-methylimidazolium tetrafluoroborate ([HMIM]BF4) and its graphene-dispersed ionic liquid based nanofluids (Ionanofluids) from room temperature to 200 °C. A thermal analyzer measured the thermal conductivity of the samples using the transient plane source (...
The Transient Plane Source method was used in this research article to measure the thermal conductivity of an Ionanofluid, highly stable graphene (GE)-based nanofluid, at various temperatures. Researchers took special note of the effects of temperature, GE loading, presence of multi-walled carbon nanotubes (MWCNTs), ...