The variability within the results presented from the guarded hot-plate (GHP) and guarded heat-flow meter (GHF) methods was determined. Multiple thermal properties of polymethyl methacrylate (PMMA) were analyzed to compare methods. These measurements are taken in the range of −70◦C and +80◦C. Providing reference data for PMMA is the main objective of this paper as well as quantifying the effects of thermal contact of the measuring instruments....
The authors used a variety of techniques to determine the thermal properties of polymethyl methacrylate (PMMA), including thermal conductivity, thermal diffusivity, specific heat and density. The measurements are performed in the temperature range from -70°C to 80°C. The results from the different techniques used to characterize the PMMA (GHP, GHF, TPS, THS) are all compared to see whether they agree with one another....